Installation Manual
Table Of Contents
- Title Page
 - Table of Contents
 - Certifications, approvals, listings, and safety
 - Introduction
 - System overview
 - Installation checklist
 - Control panel installation
 - Power supply
 - Telephone communications
 - IP communications
 - Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
 - B920 Two-line Alphanumeric Keypad
 - B921C Two-line Capacitive Keypad with Inputs
 - B930 ATM Style Alphanumeric Keypad
 - B942 Touch Screen Keypad
 - Shortcuts and custom functions
 - Address settings
 - Supervision
 - Installation and control panel wiring (keypads)
 - Sensor loops overview and wiring (B921C/B942/B942W only)
 - Output wiring (B942/B942W only)
 - Troubleshooting
 
 - Keyswitches
 - RADION keyfobs and Inovonics pendant transmitters
 
 - Keypads
 - On-board outputs
 - Off-board outputs
 - On-board points
 - Off-board points
 - Wireless modules
 - Access control
 - Program and test the control panel
 - Control panel board overview
 - System wiring diagrams
 - Approved applications
 - Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
 - [1] Reporting > [2] Network menu parameters
 - [1] Reporting > [3] Routing menu parameters
 - [1] Reporting > [4] Personal Note menu parameters
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
 - [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
 - [3] RPS > [1] RPS Passcode menu parameters
 - [3] RPS > [2] RPS Phone Number menu parameters
 - [3] RPS > [3] RPS IP Address menu parameters
 - [3] RPS > [4] RPS Port Number menu parameters
 - [4] Area Options menu parameters
 - [5] Keypad menu parameters
 - [6] Users menu parameters
 - [7] Points menu parameters
 - [8] Disable Programming menu
 
 - [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
 - [1] RF Point Menu> [2] Replace Point RFID
 - [1] RF Point Menu> [3] Remove Point RFID
 - [2] RF Repeater Menu > [1] Add Repeater
 - [2] RF Repeater Menu > [2] Replace Repeater
 - [2] RF Repeater Menu > [3] Remove Repeater
 - [3] RF Diagnostic Menu > [1] RF Points
 - [3] RF Diagnostic Menu > [2] RF Repeater Menu
 
 - [3] Diags menu
 - [4] Serv Byp (Service Bypass) menu
 - [5] Versions menu
 - [6] Cloud menu
 
 - [1] Program menu
 - Specifications
 - Appendix
 - Back Page
 
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Relay Set by User NsD28 NidiiiiRCrrrr Sounder/Relay Set 1 320 00 000
Remote Reset – System was
reset by RPS
NsD11 NRN System Reset 1 305 00 000
Remove User’s Key Fob
(Assign Card Event)
NsD30 NidiiiiDAuuuu Local Only Local Only
Replace Sensor Tpppp NriaaBTpppp Maintenance Alert 1 393 aa ppp
Replace Sensor Restore Rpppp NriaaBRpppp Maintenance Alert Restore 3 393 aa ppp
Replace User’s Key Fob
(Assign Card Event)
NsD30 NidiiiiDAuuuu Local Only Local Only
Restoral Rpppp NriaaBRpppp Sensor Trouble Restore 3 380 aa ppp
Restoral from Alarm Rpppp NriaaBHpppp Burglary Restore 3 130 aa ppp
RF Interference TsD08 NpiddddXQ RF RCVR Jam 1 344 00 
1
zzz
RF Interference Restore RsD08 NpiddddXH RF RCVR Jam Restore 3 344 00 
1
zzz
RF Transmitter Hss001 NriaaFRpppp Maintenance Alert Restore 3 393 aa ppp
RF Transmitter Low Battery Tspppp NriaaXTpppp RF Low Battery 1 384 aa ppp
RF Transmitter Low Battery
(Key Fob)
TsD10 NidiiiiXT Battery Test Failure 1 309 00 uuu
RF Transmitter Low Battery
(Key Fob) Restore
RsD10 NidiiiiXR Battery Test Restore 3 309 00 uuu
RF Transmitter Low Battery
Restore
Rspppp NriaaXRpppp RF Low Battery 3 384 aa ppp
RF Transmitter Maintenance Gss001 NriaaFTpppp Maintenance Alert 1 393 aa ppp
ROM Checksum Fail AsD12 NYX ROM Checksum bad 1 304 00 000
SDI Device AC Fail TsssD NEP Exp. Module AC Loss 1 342 00 
1
zzz
SDI Device AC Fail Restore RsssD NEQ Exp. Module AC Restore 3 342 00 
1
zzz
SDI device is missing TssssD NpiddddET Expansion Module Failure 1 333 00 000
SDI device is restored RssssD NpiddddER Expansion Module Failure
Restore
3 333 00 000
SDI Device Low Battery TsssDt NpiddddEBbb Exp. Module Low Batt. 1 338 00 
1
zzz
SDI Device Low Battery
Restore
RsssDt NpiddddEVbb Exp. Module Batt. Restore 3 338 00 
1
zzz
SDI Device Missing TsssDt NpiddddEM Exp. Module Failure 1 333 00 
1
zzz
SDI Device Missing Battery TsssDt NpiddddEBbb Exp. Module Low Batt.
Restore
3 338 00 
1
zzz
158 en | Appendix Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.