Installation Manual
Table Of Contents
- Title Page
 - Table of Contents
 - Certifications, approvals, listings, and safety
 - Introduction
 - System overview
 - Installation checklist
 - Control panel installation
 - Power supply
 - Telephone communications
 - IP communications
 - Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
 - B920 Two-line Alphanumeric Keypad
 - B921C Two-line Capacitive Keypad with Inputs
 - B930 ATM Style Alphanumeric Keypad
 - B942 Touch Screen Keypad
 - Shortcuts and custom functions
 - Address settings
 - Supervision
 - Installation and control panel wiring (keypads)
 - Sensor loops overview and wiring (B921C/B942/B942W only)
 - Output wiring (B942/B942W only)
 - Troubleshooting
 
 - Keyswitches
 - RADION keyfobs and Inovonics pendant transmitters
 
 - Keypads
 - On-board outputs
 - Off-board outputs
 - On-board points
 - Off-board points
 - Wireless modules
 - Access control
 - Program and test the control panel
 - Control panel board overview
 - System wiring diagrams
 - Approved applications
 - Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
 - [1] Reporting > [2] Network menu parameters
 - [1] Reporting > [3] Routing menu parameters
 - [1] Reporting > [4] Personal Note menu parameters
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
 - [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
 - [3] RPS > [1] RPS Passcode menu parameters
 - [3] RPS > [2] RPS Phone Number menu parameters
 - [3] RPS > [3] RPS IP Address menu parameters
 - [3] RPS > [4] RPS Port Number menu parameters
 - [4] Area Options menu parameters
 - [5] Keypad menu parameters
 - [6] Users menu parameters
 - [7] Points menu parameters
 - [8] Disable Programming menu
 
 - [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
 - [1] RF Point Menu> [2] Replace Point RFID
 - [1] RF Point Menu> [3] Remove Point RFID
 - [2] RF Repeater Menu > [1] Add Repeater
 - [2] RF Repeater Menu > [2] Replace Repeater
 - [2] RF Repeater Menu > [3] Remove Repeater
 - [3] RF Diagnostic Menu > [1] RF Points
 - [3] RF Diagnostic Menu > [2] RF Repeater Menu
 
 - [3] Diags menu
 - [4] Serv Byp (Service Bypass) menu
 - [5] Versions menu
 - [6] Cloud menu
 
 - [1] Program menu
 - Specifications
 - Appendix
 - Back Page
 
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Missing Supervision MTpppp NriaaBZpppp Loss of Supervision –RPM 1 382 aa ppp
Missing Trouble Vpppp NriaaUYpppp Loss of Supervision - RPM 1 382 aa ppp
Network Cable Connected NsD43 NpiddddNR010 System Peripheral Trouble
Restore
3 330 00 zzz
Network Cable Disconnected NsD42 NpiddddNT010 System Peripheral Trouble 1 330 00 zzz
Non-Fire Cancel Alarm \siiii Nriaa/idiiiiBC Cancel 1 406 aa uuu
Normal start-up of the
control panel
NsD14 NRR System Reset 1 305 00 000
Opening by Account OSiiii NidiiiiOP O/C by account 1 401 00 uuu
Opening by Area Osiiii Nriaa/idiiiiOP O/C by user 1 401 aa uuu
Opening Early by Area Osiiii Nriaa/idiiiiOK Early O/C 1 451 aa uuu
Opening Late by Area Osiiii Nriaa/idiiiiOJ Late O/C 1 452 aa uuu
Parameters changed NsD02 NYG Panel Programming
Changed
1 306 00 000
Personal Notification
Communication Trouble
TsB01 NpiddddYS Communication Trouble 1 350 0 zzz
Personal Notification
Communication Trouble
Restore
NsB01 NpiddddYK Communication Trouble
Restore
3 350 0 zzz
Phone Line Missing 1 TsssB NLT1 Telco 1 Fault 1 351 00 000
Phone Line Restored 1 RsssB NLR1 Telco 1 Fault Restore 3 351 00 000
Popex Bus Fault TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Bus Fault Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Popex Invalid Popit TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Invalid Popit Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Popex Low Voltage TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Low Voltage Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Programming Started TsssF NiduuuuTS System Shutdown 1 308 00 iii
Programming Finished RsssF NiduuuuTE System Shutdown Restore 3 308 00 iii
RAM Fail with RPS TsF02 NRA Unsuccessful access 1 413 00 000
Re-Boot NsD14t NRR System Reset 1 305 00 000
Relay Reset by Sked NsD20 NaikkkROrrrr Sounder/Relay Reset 3 320 00 000
Relay Reset by User NsD18 NidiiiiROrrrr Sounder/Relay Reset 3 320 00 000
Relay Set by Sked NsD19 NaikkkRCrrrr Sounder/Relay Set 1 320 00 000
Control Panel Appendix | en 157
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180