Installation Manual
Table Of Contents
- Title Page
 - Table of Contents
 - Certifications, approvals, listings, and safety
 - Introduction
 - System overview
 - Installation checklist
 - Control panel installation
 - Power supply
 - Telephone communications
 - IP communications
 - Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
 - B920 Two-line Alphanumeric Keypad
 - B921C Two-line Capacitive Keypad with Inputs
 - B930 ATM Style Alphanumeric Keypad
 - B942 Touch Screen Keypad
 - Shortcuts and custom functions
 - Address settings
 - Supervision
 - Installation and control panel wiring (keypads)
 - Sensor loops overview and wiring (B921C/B942/B942W only)
 - Output wiring (B942/B942W only)
 - Troubleshooting
 
 - Keyswitches
 - RADION keyfobs and Inovonics pendant transmitters
 
 - Keypads
 - On-board outputs
 - Off-board outputs
 - On-board points
 - Off-board points
 - Wireless modules
 - Access control
 - Program and test the control panel
 - Control panel board overview
 - System wiring diagrams
 - Approved applications
 - Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
 - [1] Reporting > [2] Network menu parameters
 - [1] Reporting > [3] Routing menu parameters
 - [1] Reporting > [4] Personal Note menu parameters
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
 - [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
 - [3] RPS > [1] RPS Passcode menu parameters
 - [3] RPS > [2] RPS Phone Number menu parameters
 - [3] RPS > [3] RPS IP Address menu parameters
 - [3] RPS > [4] RPS Port Number menu parameters
 - [4] Area Options menu parameters
 - [5] Keypad menu parameters
 - [6] Users menu parameters
 - [7] Points menu parameters
 - [8] Disable Programming menu
 
 - [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
 - [1] RF Point Menu> [2] Replace Point RFID
 - [1] RF Point Menu> [3] Remove Point RFID
 - [2] RF Repeater Menu > [1] Add Repeater
 - [2] RF Repeater Menu > [2] Replace Repeater
 - [2] RF Repeater Menu > [3] Remove Repeater
 - [3] RF Diagnostic Menu > [1] RF Points
 - [3] RF Diagnostic Menu > [2] RF Repeater Menu
 
 - [3] Diags menu
 - [4] Serv Byp (Service Bypass) menu
 - [5] Versions menu
 - [6] Cloud menu
 
 - [1] Program menu
 - Specifications
 - Appendix
 - Back Page
 
R
Y
G
B
2
1
Figure 8.4: B426 to Ethernet wiring
Callout ᅳ Description
1 ᅳ B426 module
2 ᅳ Ethernet cable
Diagnostic LEDs
The B426 includes the following on-board LEDs to assist with troubleshooting:
– Heartbeat (system status).
– RX (receive).
– TX (transmit).
Refer to B426 module overview for Ethernet link LED locations.
Flash pattern Function
Flashes once every 1 sec
Normal state. Indicates normal operation state.
3 quick flashes every 1 sec
Communication error state. Indicates a bus communication
error. The module is not receiving commands from the
control panel.
 On Steady
Trouble state. Indicates a trouble condition exists.
 Off
LED trouble state. Module is not powered, or some other
trouble condition prohibits the module from controlling the
heartbeat LED.
Table 8.5: Heartbeat LED descriptions
8.3.6
48 en | IP communications Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.