Installation Manual
Table Of Contents
- Title Page
 - Table of Contents
 - Certifications, approvals, listings, and safety
 - Introduction
 - System overview
 - Installation checklist
 - Control panel installation
 - Power supply
 - Telephone communications
 - IP communications
 - Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
 - B920 Two-line Alphanumeric Keypad
 - B921C Two-line Capacitive Keypad with Inputs
 - B930 ATM Style Alphanumeric Keypad
 - B942 Touch Screen Keypad
 - Shortcuts and custom functions
 - Address settings
 - Supervision
 - Installation and control panel wiring (keypads)
 - Sensor loops overview and wiring (B921C/B942/B942W only)
 - Output wiring (B942/B942W only)
 - Troubleshooting
 
 - Keyswitches
 - RADION keyfobs and Inovonics pendant transmitters
 
 - Keypads
 - On-board outputs
 - Off-board outputs
 - On-board points
 - Off-board points
 - Wireless modules
 - Access control
 - Program and test the control panel
 - Control panel board overview
 - System wiring diagrams
 - Approved applications
 - Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
 - [1] Reporting > [2] Network menu parameters
 - [1] Reporting > [3] Routing menu parameters
 - [1] Reporting > [4] Personal Note menu parameters
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
 - [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
 - [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
 - [3] RPS > [1] RPS Passcode menu parameters
 - [3] RPS > [2] RPS Phone Number menu parameters
 - [3] RPS > [3] RPS IP Address menu parameters
 - [3] RPS > [4] RPS Port Number menu parameters
 - [4] Area Options menu parameters
 - [5] Keypad menu parameters
 - [6] Users menu parameters
 - [7] Points menu parameters
 - [8] Disable Programming menu
 
 - [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
 - [1] RF Point Menu> [2] Replace Point RFID
 - [1] RF Point Menu> [3] Remove Point RFID
 - [2] RF Repeater Menu > [1] Add Repeater
 - [2] RF Repeater Menu > [2] Replace Repeater
 - [2] RF Repeater Menu > [3] Remove Repeater
 - [3] RF Diagnostic Menu > [1] RF Points
 - [3] RF Diagnostic Menu > [2] RF Repeater Menu
 
 - [3] Diags menu
 - [4] Serv Byp (Service Bypass) menu
 - [5] Versions menu
 - [6] Cloud menu
 
 - [1] Program menu
 - Specifications
 - Appendix
 - Back Page
 
2. Go to [1] Program > [2] Network > [2] Cellular > (choose the SDI2 cellular module or
plug-in module) > [1] SIM APN. The keypad shows the current configuration.
3. Press [ENTER] to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press [ENTER] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of SIM APN
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [2] Cellular > (choose the SDI2 cellular module or
plug-in module) > [1] SIM APN. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [Edit] to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press [Save] to save the changes.
6. When the keypad shows Parameter Saved, escape from the menu.
SIM Username
B91x/B92x keypads configuration of SIM Username
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [2] Cellular > (choose the SDI2 cellular module or
plug-in module) > [2] SIM Username. The keypad shows the current configuration.
3. Press [ENTER] to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press [ENTER] to save the changes.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of SIM Username
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [2] Cellular > (choose the SDI2 cellular module or
plug-in module) > [2] SIM Username. The keypad shows the UPnP current configuration.
3. Press [Edit] to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press [Save] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
SIM Passcode
B91x/B92x keypads configuration of SIM Passcode
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [2] Cellular > (choose the SDI2 cellular module or
plug-in module) > [3] SIM Passcode. The keypad shows the current configuration.
3. Press [ENTER] to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press [ENTER] to save the changes.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of SIM Passcode
1. Enter the installer passcode, and then open the [1] Installer menu.
120
en | Keypad Installer menu Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.