Technical data

Use the 6-bit dip switch (Camera Control Protocol Switch) to set the camera’s control
protocol and its baud rate. If protocol “Pelco D” is selected, which is switch no. 01 and baud
rate 4800, for instance, set the SW-1 to “ON” and the rest to “OFF” as shown below.
ON
1 2 3 4 5 6
123456
For more switch configurations, refer to Appendices, page 69.
Power Connector
Before connecting the power wires, refer to the illustrations below for definition of the power
connector. Be sure to connect to the correct position.
Power
Connector
Switch
Number
Description
SW1 AC 24V_1 (24 VAC)
SW2 GND (Ground)
SW3 AC24V_2 (24 VAC)
Alarm I/O
The camera supports 4 digital alarm inputs and 2 digital alarm outputs. Make sure the alarm
connections are properly wired before starting to configure alarm related settings. Refer to
the pin definition table below for alarm system wiring.
1 ALARM_OUT_NO_1 7 ALARM_OUT_COM_2
2 ALARM_OUT_NC_1 8 GND
3 ALARM_OUT_COM_1 9 ALARM_IN_4
4 GND 10 ALARM_IN_3
5 ALARM_OUT_NO_2 11 ALARM_IN_2
6 ALARM_OUT_CN_2 12 ALARM_IN_1
5.5
5.6
18 en | Connection AUTODOME 5000 Analog PTZ Camera
2013.07 | 1.3 | Operations Manual Bosch Security Systems, Inc.