Technical data

For users who wish to set up the camera ID via the dip switch at the camera’s back plate, first
choose <HW> as the setting type under the <ID SETTING> menu. Then the camera’s ID can be
setup using the 10-bit ID dip switch. If the camera’s ID number is 6, for instance, the ID switch
SW 2 and SW 3 should be set to “ON” and the rest should be set to “OFF” as shown below.
ON
1 2 3 4 5 6 7 8 9 10
For switch configuration details, refer to Appendices, page 69.
Notice!
If you need to setup the camera ID via the dip switch at the camera’s back plate, the setting
type MUST be changed to <HW>. Otherwise the dip switch WILL NOT be enabled.
Camera Control Protocol Setting
Define the camera control protocol according to the devices of the surveillance system.
Generally, use one protocol even the devices are provided from different manufacturers. Refer
to the table below for all supported protocols with their matching switch numbers and baud
rate. Choose an appropriate protocol for the camera.
Switch
Number
Protocol Baud Rate
00 Pelco D 2400
01 Pelco D 4800
02 Pelco D 9600
04 Pelco P 1200
05 Pelco P 4800
06 Pelco D 9600
10 Bosch OSRD 9600
5.4
AUTODOME 5000 Analog PTZ Camera Connection | en 17
Bosch Security Systems, Inc. Operations Manual 2013.07 | 1.3 |