AMC2 4W Installing | en 47
Bosch Sicherheitssysteme GmbH Installation manual | V 7.6 | 2008.12
Wiegand reader type W 4
The reader has an additional DIL switch to choose the following
parameter settings.
1 green LED
2red LED
3 Data 0
4 Data 1
5-
6 Reader Supply - 0V
7 Reader Supply: 8 - 30VDC
8-
9-
10 -
S1 = on The beeper is controlled by input 1.
S2 = on The beeper will allways be set after
card reading.
S3 = on The LED displays will be controlled by
the reader.
S4 = off
S5 = on The beeper is controlled by input 2.
i
NOTICE!
In the default delivery status pin 2 is set to ON.