Installation Manual

AMC2 4W Installing | en 45
Bosch Sicherheitssysteme GmbH Installation manual | V 7.6 | 2008.12
Wiegand reader type W 2
This wiring diagram refers to the following readers from the
BOSCH catalog:
i
NOTICE!
The terminal assignment shown above does not apply to the W1
readers ARD-R90-AKT00 (F.01U.030.232) and ARD-R90
(F.01U.027.003). Please use instead the installation guide of
the card reader itself.
The Wiegand reader interface of the the AMC2 4W does not
provide sufficient power for the ARD-R90. Please plan an
external power supply for the ARD-R90.
CTN Part Number
ARD-P0834-01 F.01U.028.449
ARD-H0834-01 F.01U.028.448
ARD-W2626-01 F.01U.028.443
ARD-W2634-01 F.01U.028.444
ARD-Prox26-01 F.01U.028.446
1 red Power supply - 12 V+
2 black Reader Supply - 0V
3 green Data 0
4 white Data 1 (clock)
5 purple shield
6brown green LED
7-
8-
9-
10 -