Installation Manual

AMC2 4W Installing | en 43
Bosch Sicherheitssysteme GmbH Installation manual | V 7.6 | 2008.12
5.13 Wiegand Interface for Card Readers
The AMC2 4W provides four ports for connecting a maximum of
4 readers with Wiegand interfaces. Each interface is connected
using a 10-pin pluggable screw connector (S2, S7, S14, and
S19) - refer to Figure 7.3.
Figure 5.19 Location of the Wiegand interfaces for external devices
These interfaces are point-to-point connections, and each can
support only a single reader with a maximum cable length of
150m (492 ft). Readers are addresssed according to their
respective interface numbers.
Refer to Table 7.4 for a complete wiring diagram of the Wiegand
reader interface.