Specifications

6 720 644 956
Appliance details
5
2 Appliance details
2.1 Features
Parts
Key Pad interface control
High power pre-mix compact burner with low NOx
emissions
Modulating Gas Valve with constant gas:air ratio
control
Modulating water valve for improved comfort and
temperature control.
High quality materials for long working life
Copper heat exchanger
High efficiency Ceramat Burner
Compact space saver: mounts on a wall with a
supplied bracket.
Features
Real-time diagnostics for troubleshooting/
informational purposes
LCD Display with backlight
On/Off and Temperature control switches
Reset button
Program button (Selectable temperature default)
Failure codes for easy diagnostics and repair
Easily removable one-piece cover
Built in freeze prevention
1)
.
Accessories (Bosch part #)
Optional wireless remote control accessory to
operate with the appliance (TSTAT2)
Cascading kit (7709003962)
External water filter (8703305356)
Gas conversion kit (8719002176)
Pipe Cover (PTPCES)
Recess box (7736500043)
Pressure relief valve (FWL-2).
2.2 Specifications (Technical data)
Approved in US/Canada
Capacity
Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.
Maximum output
160,500 Btu/h (47.0 kW)
Maximum input
199,000 Btu/h (58.3 kW)
Efficiency in %
Thermal efficiency > 82%
Min. Input
19,900 Btu/h (5.8 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C)
Default temperature: 122°F (50°C)
Stability: +/- 2°F (+/- 1°C)
Gas Requirement
Gas connection (inches) - ¾”
Inlet gas pressure under operation (with a high hot
water flow rate)*
Propane: 8” - 13” water column
Natural Gas: 3.5” - 10.5” water column.
* To measure gas pressure, see Measuring Gas
Pressure, chapter 6.6, page 24.
Water
Hot water connection (inches) - ¾”
Cold water connection (inches) - ¾”
Water valve material: Polymer (PPS) (Polypropylene
Sulfid)
Minimum water flow: 0.5 gallon/minute (1,9 l/m).
Note: Activation varies with inlet water temperatures
from 0.5 - 1.6 gallon/minute (1.9 - 6.1 l/m).
Minimum recommended water pressure: 30 PSI
(2.07 bar).
Minimum well pressure 40 psi, see page 20.
Connections:
Bottom of heater
Combustion
NOx 40 Ng/J
(Nanograms of NOx (calculated as NO
2
) per
Joule of heat output).
CO 250 ppm (measured)
CO
2
level set from factory, see chapter 9.4, page 33.
1) The freeze prevention kit is designed to provide
protection for the water heater down to approximately
5°F for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing
outside the appliance from freezing. Precautions should
be taken.
i
BOSCH is constantly improving its
products, therefore specifications are