940 ES Performance Data
Maximum Gas Input (BTU) 199,000
Minimum Input (BTU) 19,900
Maximum Output (BTU) 160,500
Minimum Output (BTU) 18,300
Thermal Ef ciency 83%
940 ES Operational Data
Weight (lbs.) 67
Min. Inlet Gas Pressure NG("WC) / LP("WC) 3.5 / 8
Max. Inlet Gas Pressure NG("WC) / LP("WC) 10.5 / 13
940 ES Maximum Output Temperature (°F) 140°F
Flow Rate at 35°F T (GPM) 9.4
Flow Rate at 45°F T (GPM) 7.2
Flow Rate at 50°F T (GPM) 6.6
Flow Rate at 60°F T (GPM) 5.5
Max. Working Pressure (psi) 150
Min. Working Pressure (psi) 30
Min. Activation Flow (GPM) 0.5
Relief Valve Pressure Rating (psi) 150
Venting Category III
940 ES Approved Venting Material
Item Diameter Material
Exhaust
Vent
3 or 4 inches
Sealed single wall stainless steel
(AL29-4C)
Intake
Vent
3 or 4 inches
Sealed PVC or any other rigid pipe
940 ES Clearances
Minimum Clearance
to Combustibles
(Inch)
Front 1
Rear 0
Side 1
Floor 12
Additional Information
Low NOx emissions
Modulating water valve to improve temperature
stability
Modulating premix burner with constant gas/air ratio
Direct-vent sealed combustion
Direct spark ignition
150 psi relief valve included
Concentric termination available
LCD display with backlight / control buttons
100% copper heat exchanger
Options
Wireless remote control (TSTAT2)
Cascading kit (77090003962)
Outdoor kit (BTOK)
• External water lter (8703305356)
Concentric termination kit (ESHCK)
Exhaust/Intake bird screen (L2594)
Gas conversion kit (8 719002176)
Pipe Cover (PTPCES)
High temperature kit (7736500074)
Recess box kit (7736500043)
Pressure relief valve (FWL-2).
Note: Refer to installation and applications manual for speci c
information on venting, piping, electrical connections, and
pump sizing.
0
1
2
3
4
5
6
7
10 20 30 40 50 60 70 80 90
Degree rise (°F)
GPM
9
10
11
0
1
2
3
4
5
6
7
0
20
30
4
0 5
0
60
7
0
80
90
Degree rise (°F)
G
P
M
9
1
0
9
4
0 E
S
1
1
940 ES Degree rise versus flow rate