Specifications

Appliance details | 7
6 720 644 936 (2013/01)830 ES
3.2 Specifications (Technical data)
Approved in US/Canada
Safety devices
Flame failure device (ionization flame rod sensor)
Overheat prevention (temperature limiter)
Inlet temperature sensor
Outlet temperature sensor
Back flow temperature sensor
3.3 Unpacking the heater
Before installing the unit, be certain you have the correct heater for
your type of Gas - Propane or Natural Gas. Identification labels are
found on the shipping box, and on the rating plate which is located on the
right side panel of the cover.
Fig. 2 Rating plate
[A] Serial number
[B] Type of gas
Technical characteristics Units 830 ES
Capacity
Maximum flow rate at a 25 °F
(13.9 °C) rise
GPM (l/min) 11.6 (43.8)
Maximum flow rate at a 35 °F
(19.4 °C) rise
GPM (l/min) 8.3 (31.3)
Maximum flow rate at a 45 °F
(25 °C) rise
GPM (l/min) 6.4 (24.4)
Maximum flow rate at a 55 °F
(30.6 °C) rise
GPM (l/min) 5.3 (19.9)
Maximum flow rate at a 75 °F
(41.7 °C) rise
GPM (l/min) 3.9 (14.6)
Maximum flow rate at a 90 °F
(50 °C) rise
GPM (l/min) 3.2 (12.2)
Maximum output BTU/hr (kW) 147,000 (43)
Maximum input BTU/hr (kW) 175,000 (51.2)
Thermal efficiency (Efficiency
in %)
% > 83%
Minimum Input BTU/hr (kW) 19,900 (5.8)
Temperature Control
Selection range °F ( °C) 100 - 140 (38 - 60)
Default temperature °F ( °C) 122 (50)
Stability °F ( °C) 2 ( 1)
Gas Requirement
Gas connection inches ¾"
Peak load inlet gas pressure
1)
Propane water column 8” - 13”
Natural Gas water column 3.5” - 10.5”
Water
Hot water connection inches ¾"
Cold water connection inches ¾"
Minimum water flow
2)
GPM (l/min) 0.5 (1.9)
Minimum recommended
water pressure
PSI (bar) 30 (2.07)
Minimum well pressure PSI 40
Water valve material Polymer (PPS)
(Polypropylene
Sulfide)
Connections: Bottom of heater
Combustion
CO level ppm 250 (measured)
CO
2
level (set from factory) % see table 35
Dimensions
Depth inches (mm) 11 ¼ (286)
Width inches (mm) 17
7
/
8
(452)
Height inches (mm) 30½ (775)
Table 3
Weight pounds (kg) 67 (30.5)
Gas types
Natural Gas
LP Gas
Voltage
Nominal V AC 120
Frequency Hz 60
Amperage
Idle mA 40
Operation A 2.5
Noise db (A) 45 - 65
Water protection
3)
IP X4D
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.14, page 31.
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9
- 6.1 l/m).
3) Protection against water drops.
If appliance is installed at elevations above 2000ft, refer
to chapter 4.3.8 Fan speed adjustment.
Technical characteristics Units 830 ES
Table 3