User guide

Chapter 4. User Interface Options
137
Enabling and
Disabling the
Drive(s)
DRIVE 1: ON DRIVE 2: ON
ON OFF ON OFF
COMPUMOTOR NNNN MOTION CONTROLLER
RUN JOG STATUS DRIVE DISPLAY ETC
In the DRIVE menu, the current status of
the drive(s) is displayed. To enable or
disable the drive #1, press
F1
or
F2
. To
enable or disable the drive #2, press
F3
or
F4
. This menu offers the same
functionality as the DRIVE command.
WARNING
Shutting down a rotary drive system allows the load to freewheel if there is no brake installed.
6270: Shutting down a valve/cylinder system returns the valve to the null position.
Access Security
COMPUMOTOR NNNN MOTION CONTROLLER
GO-BACK REV RESET SETUPS ETC
COMPUMOTOR NNNN MOTION CONTROLLER
ACCESS RUN
COMPUMOTOR NNNN MOTION CONTROLLER
RUN JOG STATUS DRIVE DISPLAY ETC
Access
Denied
Access Approved
ACCESS xxxx
Enter password then press ENTER
Default menu after changing DPASS
If the RP240 password is
modified with the DPASS
command to be other than
the default (see Changing
the Password below) the
ACCESS menu then
becomes the new default
menu after power-up or
executing a RESET.
After that, the new
password must then be
entered to access the
original default menu (see “Access Approved” path in illustration). If the operator does not
know the new password, all he or she can do is run programs stored in the 6000 product (RUN).
Changing the Password: The default password is the root name for your product (e.g., “6250”
for the OEM6250, “6104” for the ZETA6104, “6250” for the 6250). A new password
(numeric value of up to 4 characters) can be established with the DPASS command. For
example, the DPASS2001 command sets the password to 2001.
Revision Levels
COMPUMOTOR NNNN MOTION CONTROLLER
GO-BACK REV RESET SETUPS ETC
COMPUMOTOR NNNN MOTION CONTROLLER
RUN JOG STATUS DRIVE DISPLAY ETC
6250 REV: 92-013471-01-5.0 6250
DSP REV: 92-013812-01-5.0 DSP RP240
RP240 REVISION: 92-012951-01B
Resetting the
6000 Product
COMPUMOTOR NNNN MOTION CONTROLLER
GO-BACK REV RESET SETUPS ETC
COMPUMOTOR NNNN MOTION CONTROLLER
RUN JOG STATUS DRIVE DISPLAY ETC
CONFIRM RESET
YES NO
After accessing the RESET menu,
press the
F1
key to execute a reset (or
press
F2
to cancel and exit the
menu). The reset is identical to
issuing a RESET command or cycling
power to the 6000 product. If a start-
up program has been assigned with
the STARTP command, that program
will be executed.
CAUTION
Executing a reset will restore most command values (exclusions: see page 33) to their
factory default setting.