Solution 144 Control Panel Data Sheet

Chime Mode
Chime mode allows monitoring a zone or group of
zones by sounding the keypad buzzer or activating a
programmable output. This feature is ideal to monitor
business entry doors for customer entry during
business hours.
Separate Tamper Inputs
Both the Solution 144 Control Panel and most panel
modules feature a separate tamper input making
remote locating devices in a secure enclosure easy.
Walk test
Enables a user to test all zones within an area at the
same time. When the walk test feature is activated, the
code pad will display a list of areas available to walk
test. Once the area to test is selected all zones within
the area will be displayed. The user then walks the
area and zones successfully tested will be removed
from display leaving only those that failed to be
activated on the code pad screen.
Partitioning up to 8 Areas
The control panel supports up to 8 separate areas with
no restriction on the number of individual zones that
can belong in an area. You can arm and disarm the
control panel by area, alternatively, you can arm and
disarm several areas at the same time.
Multiple areas can be linked to a shared area which is
automatically controlled (hallway or lobby). Area
arming may be conditional on other areas (master or
associate).
Programmable Outputs
The Solution 144 Control panel supports 5 on board
outputs and is expandable to 37 outputs in total. All
outputs are protected and will shut down individually
under an overload condition. Output conditions are
displayed on the code pad and may be reported
externally if required. Outputs may be triggered via an
event and or manually and may be programmed for
polarity, pulsing or one shot operation.
Integrated Access Control
Access control is no longer reserved only for larger
more expensive systems. Proximity technology from
Bosch provides an affordable and effective solution for
up to 16 access doors. The new LAN readers include
egress and lock control built in, which reduces cost
and simplifies installation.
Time Zones
Up to 16 time zones may be implemented. Each time
zone can have up to 4 time periods including day of
the week and holidays. Time zones may be used to
automatically arm / disarm the system at specific
times as well control user access to doors or to
automatically control outputs.
256 Users with flexible credentials and devices
Up to 256 individual users may be included in the
system. Each user can be given a unique PIN code, RF
key fob, Proximity token, and fingerprint credential if
required. The Solution 144 supports variable length
PIN codes up to 8 digits.
Variable PIN configuration
Users can be given free choice of PIN length or
alternately an exact PIN length requirement may be
enforced for higher security applications. PIN codes
can be set to expire at a pre-programmed time per
user.
Flexible Communications Options
CID, SIA, DOMESTIC and SMS Text Reporting formats
are all standard out of the box and the dual reporting
feature allows you to select which reports are sent to
which route and in what format. Open / Close
reporting can be selected individually for each user
and area on the panel allowing the owner to monitor
cleaner access, children returning home from school
or access to a particular restricted area all via their
mobile phone. Interactive voice reporting is also
available as an option.
Multi Tennant
When enabled the Multi tenant feature locks the first
128 users on the system to the first 128 zones on the
system. Each time a user enters their PIN the
corresponding zone is automatically bypassed allowing
the user to access the zone. The Multi Tennant feature
is ideal for applications such as self storage centres or
schools etc.
Delay Trouble Beeps
Setting this option will prevent any system trouble
events from sounding the code pad speaker between
the hours of 10pm until 7am. During this time, any
new trouble event will be shown in the code pad
display. If trouble events are still in effect after 7am
the code pad will begin to sound the trouble alert to
notify the user. This function is ideal for all residential
applications.
Event Log
The control panel stores up to 1000 events from all
areas. All events are recorded in the log regardless of
the reporting setting. The event log may be viewed via
the code pad or via a direct or remote connection from
the Solution Link programming software.
Advanced RS485 LAN
The control panel communicates with other system
module devices via the built in RS485 LAN or Local
Area Network.
For increased security, the system uses anti-
substitution technology and a proprietary data
encryption algorithm to communicate with all LAN
modules.
When using the recommended cable types, the LAN
can be up to 1200 metres in length, or even greater
when LAN isolators are used.
2