Specifications
54 | Personal Security Data Book
TECHNICAL SPECIFICATIONS
The receiver is not suitable for mounting in direct sunlight (indoor use only)
LBB 6010:
Power supply: 12 V dc (-10% - +20%),
275 mA max.
Freqeuncy: 420 - 474 MHz. Determined by crystal fitted.
Frequency deviation: + or - 4 kHz.
Frequency tolerance: < 2 ppm for the specified temperature range.
Sensitivity: 0.8 uV for 20 dB sinad (typical).
Channel spacing: 20 kHz (typical).
IF band width: 15 kHz.
LF band width: 20 - 3000 Hz (6dB).
Spurious emission: < 2 nW.
Co-channel rejection: > -8 dB.
Spurious rejection: > 70 dB.
Intermodulation
response ratio: > 60 dB.
Image rejection: > 70 dB.
Output level: Adjustable up to 0,775 Veff (0 dBm).
Output impedance: 25 Ohm.
Input impedance: 50 Ohm.
Squelch: Adjustable (noise + pilot tone).
Tone decoder: 155 - 255 Hz (adjustable).
Output line - DC levels:
- 30 V dc (stand by).
- 9 V dc / - 1 V dc (speech level).
+1 V dc / +9 V dc (code level).
Relative humidity: < 95%.
Bosch Security Systems B.V.
www.boschsecuritysystems.com
9498 973 01014 en 01-1 | Printed in The Netherlands | Januari 2004 • Data subject to change without notice.
Monitoring: HF signal without DP 6000 codes.
Low power supply (< 10 V dc + or - 10%).
Connections
DP 6000: - 16 pin male Hirschmann plug.
Antenna: - Female “N” - type connector.
Operating temperature: - 20°C to + 55°C.
Storage temperature: - 40°C to + 70°C.
Dimensions: 237 x 187 x 55 mm.
Weight: 1050 g.
SUPPLEMENTARY ITEMS
POWER ADAPTER LBB 5934/01
Input: 100-240 Vac
47 Hz-63 Hz
Power consumtion: 400 mA
Output: 12 Vdc
1.25A max
Operating temp: 0
0
C - 40
0
C
LBB 6015/01:
When the LBB 6110 is used in PS 6000, or dial systems, LBB 6015/01
must always be installed.
Supply voltage: 2 Vdc - 6 Vdc.
Supply current: 3.4 mA typical.
Operating temperature: - 10°to + 55°C.
Storage temperature: - 40°to + 70°C.
Layout: plug in circuit board with flexible
interconnection to LBB 6010.