Specifications
86
• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
3. Controller Functions
Para
-
2
-
Motorenumschalt
Parameter protocol!
☞
Parameter
P14
A06
Designation
G-CHANGE
FUNCT 2
Function
assignment to
motor
additional encoder input is used as input
for the motor feedback of motor 2
value range or value
< 1 >
< 2 >
< 4 >
S R Q
- motor 1
- motor 2
Fkt
-
2Motor
X2/11
SPEED-
CHANGE 1
X2/12
SPEED-
CHANGE 2
X2/36
SPEED 2
X2/35
SPEED 1
N = N
command
N = N
command
analog
output N
X2/21
X2/31
PAR 2
X2/30
PAR 1
parameter record P
P14 1 (motor 1)
parameter record Q
Q14 2 (motor 2)
motor contactor K2 switched on
by auxiliary contactor K4
motor contactor K1 switched off
by auxiliary contactor K3
acknowledge " motor 2 ON "
from motor contactor K2
duration of motor
changeover
max. 2 seconds
motor 1 motor 2
acknowledge " motor 1 OFF "
from motor contactor K1
motor
speed
Functional sequence
Figure 83: Functional sequence of two-motor changeover
Note:
Motor changeover must be completed within two seconds, otherwise
"Motor 1/2" fault message appears and drive is switched off.
The auxiliary contactors must also change the temperature sensors of
the motors, otherwise the active motor is not monitored.
• Motor 1/2
• NO TEMP
• FEEDBACK
Possible error messages in
the display
Figure 82: Parameters for two-motor changeover
Note: The values 1 or 2 must always be assigned to the G-CHANGE
parameters in the four switchable parameter records. 0 is not allowed!
No spindle position can be performed via the spindle position encoder
during two-motor changeover as the second encoder input is used for
motor feedback from the second motor.