Specifications
• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
36
2. Operating the Controllers
Procedure:
• Switch off main drive. Control voltage must not be present.
• Unplug programming module AS and replace with PDA 1.
• Plug the master programming module into the „MASTER“ connector.
• Plug the slave programming module into the „SLAVE“ connector.
• Move the operating mode switch to the left.
• Switch on the control voltage. The display now shows the checksum
of the master module and a rotating pointer, i.e., transfer running (up
to 30 seconds). If the mode switch is not set to the left-hand position,
the prompt "SWITCH" appears and the transfer commences when the
switch is moved to the left. At the end of the transfer, the display reads
"SWITCH->".
• The mode switch must now be set to the right so that the contents of
the slave EEPROM cannot be destroyed during any subsequent
power down. If the switch is in the right-hand position, the checksum
of the slave EEPROM appears along with the request to switch off the
control voltage, e.g., "4B13 OFF".
• Switch off the control voltage and remove the slave module.
• If no further duplicates are to be made, replace the PDA 1 with the
master programming module.
Do not remove the programming module when power is on. The
slave module is erased if no master module is plugged in.
During duplication, only the contents of the master EEPROM
are transferred to the slave EEPROM. The system software is
ignored. The checksums of the master and slave EEPROMs are
not compared.
Possible fault message: EEPROM
Cause: EEPROM of slave module cannot be programmed.
Remedy: Switch the unit off and use a new slave module.
Possible fault message: PARALOST
Cause: Programming module has no parameters. Values are not
loaded or parameters in software of master and slave modules do not
agree.
Remedy: Move mode switch to left and press the red key. This loads
the general parameters with which the drive can be put into service. If the
message "BASISPART" appears in the display, the loading cycle is
complete. Pressing the red key once again puts the drive into the
parameter mode. The basic parameters are not optimized for the drive
and they should be replaced by optimized values (AS/..).
2.3.6 Loading Operating Parameters via Serial Interface
Prerequisite: Serial interface on controller. (Type code field "additional
interfaces": S), device for data input such as PC, magnetic tape,
perforated tape or other control unit.
Purpose: Rapid input of parameters for mass production machines.
Parameters can be printed out. For details on data transfer process see
section 3.22, "Serial Interface".
Possible fault messages