Specifications

• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
31
2.3 The Main Spindle Drive in Parameter Mode
The main spindle drive is not ready for either power input or output.
The parameters can be tested, read and changed. They are stored in an
EEPROM on the AS programming module.
The mode selection switch must be set to the left. Control voltage must
be present.
If parameter mode is selected when the motor is rotating, the
drive brakes to a standstill and remains without torque!
Message in display:
(P01...) appears when the parameter mode is selected for the first time
after the control voltage is applied. Otherwise, the parameter displayed
is the one which was current when the operating mode was reselected.
2.3.1 Parameter Value Quick-Check
The parameter values of a programming module are stored with a
parameter checksum. This is an advantage in that the many parameter
values can be characterized by a number.
The correspondence between the current parameter values of the main
spindle drive of a machine and the values in the parameter record in the
machine file can be checked by comparing the checksums.
In standard production machines, the parameter checksum provides a
rapid check indicating that the programming modules in use contain the
correct parameter values.
The parameter checksum does not contain the value of the OFFSET
parameter (A07) since this can differ, even in identical machines.
2. Operating the Controllers
Display Definition
output state
key
pad
Operating mode switch
e.g.,
P 01 . . . . .
parameter in display
checksum in display
SUM . . . . .
first press
"accept key"
and keep
pressed then
press " "
also.
Param.-Prüfsumme
Switching into parameter
mode
Figure 10: Parameter checksum display