Specifications
• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
30
2. Operating the Controllers
Display Definition
Output status
key pad
Oper. mode switch
Motor speed,
high-resolution
Speed command
value
C
N
NO RF
NO POWER
N=NCMD
Weighting
Motor speed
± 10 V = ± MAX RPMMotor speed
The last or the last set weighting
of the N output is maintained.
over the entire
speed range
± 10 V = ± 50
1
/min
The last selected weighting of
the N output is maintained.
± 10 V = MAX RPM
(value in parameter A01)
± 10 V = MAX RPM
(value in parameter A01)
Analogue output N (X2/21)
Spindle
encoder speed
Torque command
value, no delay
M
S
The last selected weighting of
the N output is maintained.
The last selected weighting of
the N output is maintained.
± 10 V = ± 10 000
1
/min
± 10 V = drive-dependent
torque command value
Internal speed
command value
(after ramp)
± 10 V = MAX RPM
(value in parameter A01)
Spindle position
(motor position) in
∠ degrees
POS
The last selected weighting of
the N output is maintained.
± 10 V = ± 180 °
voltage in DC
bus (ZK)
current in
DC bus (ZK)
power in
DC bus (ZK)
motor winding
temperature
P . . . . . . .
T
PD
ID
UD
The last selected weighting of
the N output is maintained.
The last selected weighting of
the N output is maintained.
The last selected weighting of
the N output is maintained.
The last selected weighting of
the N output is maintained.
The last selected weighting of
the N output is maintained.
+ 10 V = + 1000 V in the DC bus (ZK)
± 10 V = rated current of the control unit
0...+ 10 V = 0...+ 150° C
± 10 V = ± 100 kW with RAC 2.2
± 50 kW with KDA 3 and RAC 3
Spindle position
(motor position) in
∠ deg. (high-resolution)
An
a
l
og
N
- 10 V.....+ 10 V = 0.044 °
^
^
^
^
^
^
^
^
^
^
^
^
^
Figure 9: Switching the analogue output N ot the internal state variables of the drive