Specifications
140
• DOK-DIAX01-MAIN+2AD+1M-ANW1-EN-E1,44 • 07.97
8. Abbreviations, Agreements, Type Codes
1. Device abbreviation: RAC
2. Series: 2
3. Version: 2
4. Rated current:
150 A 150
200 A 200
250 A 250
5. AC supply voltage:
3 x AC 400V/50…60 Hz 380
3 x AC 400V/50 Hz, 3 x AC 460V/60 Hz 460
6. Speed command value:
analogue (+/- 10 V) A
digital (16 bit parallel) D
SERCOS interface L
7. Second encoder input:
without second encoder input O
Second encoder input for spindle feedback or add. motor feedback P
Second encoder input and synchronous input
(if AS 55 and speed command value = A) Y
8. Additional interfaces:
without additional interfaces O
Position command value, digital (16 bit parallel) D
Serial interface (RS 232 C) S
Incremental encoder output I
9. Additional bleeder
without additional bleeder W
Additional bleeder (for braking with mains failure) Z
10.Type of cooling:
internal blower 1
Type code fields:
Example:
RAC 2.2 - 200 - 460 - A00 - W1
Figure 118: Type codes for RAC 2