6. Interfaces for the NC controller and feedback
The inputs and outputs are electrically isolated. If no +24V/0V are
available from the controller to supply the outputs, link terminals 18 and
19 and terminals 1 and 2.
Figure 107: Hardware of the controller inputs, signal and analogue outputs (X2)
control unit
27
23
24
25
26
28
29
30
31
32
33
34
35
36
37
POS 2
E-STOP (RAC only)
RF
RUN
POS 1
MD-RED
OSCILATE
PAR 1
PAR 2
LIMIT 1
LIMIT 2
LIMIT 4
SPEED 1
SPEED 2
EXT POS
X2 control inputs
3 AS (KDA/TDA only)
8
4
5
6
7
9
10
11
12
13
14
15
90% LOAD
READY
N = CMD
N < MIN
IN POS
TEMP WARN
LIMIT
SPEED CHANGE 1
SPEED CHANGE 2
LOAD LIMIT
RF-SLAVE
SPINDLE CONTR
signal outputs
17
2
18
shield
0V internal
+ 24V internal
19
1
+ 24 V external
0 V external
supply voltage
1
2
Bb contact
X11 ( with KDA/TDA )
X 15 ( with RAC )
22
21
20
OVM
N
M
analogue output
+ 18V
t
+ 36V
voltage level for + 24Vext
U
voltage source from
the control unit
jumper only
if + 24V
from control
unit is
lacking
24V
1A
-10....+10V
( max 5 mA )
( max 5 mA )
0.....+10V
10 µH
10 µH
0V ext +24 V ext
470 R
applies to all signal outputs
max. 50 mA
from data bus
of the control unit
10 k
2 k
12V
4k7
to data bus
of the
control unit
applies to control inputs
6k81
2k21
22k1
+ 24V
+ 18V
0V
+ 36V
0 (low)
1 (high)
+ 5V
voltage level output
5
6
12 V
ϑ
+ 24V
+ 18V
0V
+ 36V
0 (low)
1 (high)
+ 5V
voltage level input