be well ventilated. Wear personal protective equipment dur-
ing maintenance. After the maintenance, the maintenance ar-
ea should be cleaned.
Removing/Replacing the Flat-fold Filter
(see figures I1 – I2)
Replace a damaged flat-fold filter 26 immediately.
Pull the locking latch 18 and open the filter cover 36.
Grasp the flat-fold filter 26 by the fins, pull up and remove.
When taking out the flat-fold filter 26, remove any accumu-
lating dust and debris from the closing edge of the filter
cover 36 using a moist cloth.
PES and PTFE flat-fold filters can be flushed out under run-
ning water.
Insert a new or the cleaned flat-fold filter 26; observe prop-
er and tight seating.
Shut the filter cover 36 again (must be heard to engage).
Container
Wipe out the container 1 from time to time with a commercial-
ly available, non-scouring cleaning agent and allow to dry.
Level Sensors (see figure J)
Clean the level sensors 37 occasionally.
Unlock the latches 13 and remove the vacuum lid 12.
Clean the level sensors 37 with a soft cloth.
Reattach the vacuum lid 12 again and lock the latches 13.
Storage and Transport (see figure K)
Wind the mains cable around the cable holder 17.
Insert the accessories into the holders provided: Vacuum
tubes 31 in holders 19, crevice nozzle 27 in holder 20,
floor nozzle 30 in holder 21.
Undue the elastic tie-downs of the vacuum-hose holders 4
and place the vacuum hose 24 around the vacuum cleaner
lid into the holders 4.
Reattach the elastic tie-downs.
Mount the L-Boxx onto the retainers 11.
To prevent back injuries, remove a full disposal bag or dust
bag, or drain vacuumed-up fluids before transporting the
vacuum cleaner.
Carry the vacuum cleaner only by the carrying handle 10.
For transport of the vacuum cleaner, screw the plug cap 2
onto the hose connection piece 3
.
Store the vacuum cleaner in a dry room and secure it
against unauthorised use.
To lock the castors 16, actuate the castor brakes 15 by
pushing down.
Correction of Malfunctions
If a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Problem Corrective Measure
The vacuum turbine does not start.
Check mains cable, mains plug, fuse, socket outlet and filling-level sensors
37.
Mode selector switch 7 set to “Start/Stop automatic”.
Set mode selector switch 7 to the “vacuum” symbol and switch the power
tool connected to the socket outlet 5 on.
Vacuum turbine switches off.
Empty container 1.
Vacuum turbine does not restart after emptying
the container.
Switch vacuum cleaner off and wait 5 seconds; switch on again after 5 sec-
onds.
Clean level indicators 37 as well as the space between the level indicators 37
with a brush.
Vacuuming power decreases.
Remove clogs from vacuum nozzle, vacuum tubes 31, vacuum hose 24 or
flat-fold filter 26.
Replace disposal bag 25 or dust bag.
Engage filter cover 36 properly.
–Mount vacuum cleaner lid 12 properly and lock latches 13.
Replace flat-fold filter 26.
Dust escapes during vacuuming
Check proper installation of the flat-fold filter 26.
Replace flat-fold filter 26.
The automatic shut-off (wet vacuuming) does
not respond.
Clean level indicators 37 as well as the space between the level indicators 37
with a brush.
The automatic shut-off does not function with non-conductive liquids or
foam/bubbles.
Monitor the level continuously.