Information

BMA280
Data sheet
Page 94
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x3E (FIFO_CONFIG_1)
Contains FIFO configuration settings. The FIFO buffer memory is cleared and the fifo-full flag is
cleared when writing to FIFO_CONFIG_1 register.
Name
0x3E
FIFO_CONFIG_1
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
fifo_mode<1:0>
Reserved
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
Reserved
fifo_data_select<1:0>
fifo_mode<1:0>: selects the FIFO operating mode:
´00b´ BYPASS (buffer depth of 1 frame; old data is discarded),
´01b´ FIFO (data collection stops when buffer is filled with 32 frames),
´10b´ STREAM (sampling continues when buffer is full; old is discarded),
´11 reserved, do not use
fifo_data_select<1:0>: selects whether ´00b´ X+Y+Z, ´01b´ X only, ´10b´ Y only,
´11 Z only acceleration data are stored in the FIFO