Information

BMA280
Data sheet
Page 92
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x3A (OFC_OFFSET_Z)
Contains the offset compensation value for z-axis acceleration readout data.
Name
0x3A
OFC_OFFSET_Z
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
offset_z<7:4>
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
offset_z<3:0>
offset_ z<7:0>: offset value, which is subtracted from the internal filtered and unfiltered z-
axis acceleration data; the offset value is represented with two’s complement
notation, with a mapping of +127 +0.992g, 0 0 g, and -128 -1 g; the
scaling is independent of the selected g-range; the content of the
offset_z<7:0> may be written to the NVM; it is automatically restored from
the NVM after each power-on or softreset; offset_z<7:0> may be written
directly by the user; it is generated automatically after triggering the fast
offset compensation procedure for the z-axis
Register 0x3B (TRIM_GP0)
Contains general purpose data register with NVM back-up.
Name
0x3B
TRIM_GP0
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
GP0<7:4>
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
GP0<3:0>
GP0<7:0>: general purpose NVM image register not linked to any sensor-specific
functionality; register may be written to NVM and is restored after each
power-up or softreset