Information

BMA280
Data sheet
Page 85
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x32 (PMU_SELF_TEST)
Contains the settings for the sensor self-test configuration and trigger.
Name
0x32
PMU_SELF_TEST
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
reserved
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
reserved_0
self_test_sign
self_test-axis<1:0>
reserved: write ‘0x0
self_test_sign: select sign of self-test excitation as ´1´ positive, or ´0´ negative
self_test_axis: select axis to be self-tested: ´00b´ self-test disabled, ´01b´ x-axis, ´10b´
y-axis, or ´11b´ z-axis; when a self-test is performed, only the
acceleration data readout value of the selected axis is valid; after the self-
test has been enabled a delay of a least 50 ms is necessary for the read-out
value to settle