Information
BMA280
Data sheet
Page 83
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x2F (INT_D)
Contains the definition of the flat interrupt hold time and flat interrupt hysteresis.
Name
0x2F
INT_D
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
1
Content
Reserved
flat_hold_time<1:0>
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
1
Content
reserved
flat_hy<2:0>
reserved: write ‘0’
flat_hold_time<1:0>: delay time for which the flat value must remain stable for the flat interrupt
to be generated: ´00b´ 0 ms, ´01b´ 512 ms, ´10b´ 1024 ms,
´11b´ 2048 ms
flat_hy<2:0>: defines flat interrupt hysteresis; flat value must change by more than twice
the value of flat interrupt hysteresis to detect a state change. For details see
chapter 4.7.8.
‘000b’ hysteresis of the flat detection disabled