Register 0x2A (INT_8)
Contains the timing definitions for the single tap and double tap interrupts.
Name
0x2A
INT_8
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
tap_quiet
tap_shock
reserved
reserved
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
1
0
0
Content
reserved
tap_dur<2:0>
tap_quiet: selects a tap quiet duration of ‘0’ 30 ms, ‘1’ 20 ms
tap_shock: selects a tap shock duration of ‘0’ 50 ms, ‘1’75 ms
reserved: write ‘0’
tap_dur<2:0>: selects the length of the time window for the second shock event for double
tap detection according to ´000b´ 50 ms, ´001b´ 100 ms, ´010b´ 150
ms, ´011b´ 200 ms, ´100b´ 250 ms, ´101b´ 375 ms, ´110b´ 500