Information

BMA280
Data sheet
Page 71
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x1B (INT_MAP_2)
Controls which interrupt signals are mapped to the INT2 pin.
Name
0x1B
INT_MAP_2
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
int2_flat
int2_orient
int2_s_tap
int2_d_tap
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
int2_slo_no_mot
int2_slope
int2_high
int2_low
int2_flat: map flat interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_orient: map orientation interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_s_tap: map single tap interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_d_tap: map double tap interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_slo_no_mot: map slow/no-motion interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_slope: map slope interrupt to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_high: map high-g to INT2 pin: ‘0’disabled, or ‘1’ enabled
int2_low: map low-g to INT2 pin: ‘0’disabled, or ‘1’ enabled