Information

BMA280
Data sheet
Page 67
BST-BMA280-DS000-11 | Revision 1.8 | August 2014 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Register 0x17 (INT_EN_1)
Controls which interrupt engines in group 1 are enabled.
Name
0x17
INT_EN_1
Bit
7
6
5
4
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
reserved
int_fwm_en
int_ffull_en
data_en
Bit
3
2
1
0
Read/Write
R/W
R/W
R/W
R/W
Reset
Value
0
0
0
0
Content
low_en
high_en_z
high_en_y
high_en_x
reserved: write ‘0’
int_fwm_en: FIFO watermark interrupt: ‘0’disabled, or ‘1’ enabled
int_ffull_en: FIFO full interrupt: ‘0’disabled, or ‘1’ enabled
data_en data ready interrupt: ‘0’disabled, or ‘1 enabled
low_en: low-g interrupt: ‘0’disabled, or ‘1’ enabled
high_en_z: high-g interrupt, z-axis component: 0’disabled, or ‘1’ enabled
high_en_y: high-g interrupt, y-axis component: 0’disabled, or ‘1’ enabled
high_en_x: high-g interrupt, x-axis component: ‘0’disabled, or ‘1’ enabled