Register 0x0E (FIFO_STATUS)
The register contains FIFO status flags.
Name
0x0E
FIFO_STATUS
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
fifo_overrun
fifo_frame_counter<6:4>
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
fifo_frame_counter<3:0>
fifo_overrun: FIFO overrun condition has ‘1’ occurred, or ‘0’not occurred; flag can be
cleared by writing to the FIFO configuration register FIFO_CONFIG_1 only
fifo_frame_counter<6:4>: Current fill level of FIFO buffer. An empty FIFO corresponds to
0x00. The frame counter can be cleared by reading out all frames from the
FIFO buffer or writing to the FIFO configuration register FIFO_CONFIG_1.