Note: Specifications within this document are subject to change without notice.
Register 0x04 (ACCD_Y_LSB)
The register contains the least-significant bits of the Y-channel acceleration readout value.
When reading out Y-channel acceleration values, data consistency is guaranteed if the
ACCD_Y_LSB is read out before the ACCD_Y_MSB and shadow_dis=’0’. In this case, after the
ACCD_Y_LSB has been read, the value in the ACCD_Y_MSB register is locked until the
ACCD_Y_MSB has been read. This condition is inherently fulfilled if a burst-mode read access
is performed. Acceleration data may be read from register ACCD_Y_LSB at any time except
during power-up and in DEEP_SUSPEND mode.
Name
0x04
ACCD_Y_LSB
Bit
7
6
5
4
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
acc_y_lsb<5:2>
Bit
3
2
1
0
Read/Write
R
R
R
R
Reset
Value
n/a
n/a
n/a
n/a
Content
acc_y_lsb<1:0>
undefined
new_data_y
acc_y_lsb<5:2>: Upper 4 bits of least significant 6 bits of acceleration read-back value; (two’s-
complement format)
acc_y_lsb<1:0>: Lower 2 bits of least significant 6 bits of acceleration read-back value; (two’s-
complement format)
undefined: random data; to be ignored
new_data_y: ‚0’: acceleration value has not been updated since it has been read out last
‚1’: acceleration value has been updated since it has been read out last