RF1100 Installation Instructions EN Wireless Glass Break Transmitter
RF1100 | Installation Instructions | Trademarks Trademarks Duracell® is a registered trademark of The Gillette Company. Eveready™ is a trademark of Eveready Battery Company, Inc. Panasonic® is a registered trademark of Matsushita Electric Industrial Co., Ltd.
RF1100 | Installation Instructions | 1.0 Installation Considerations . 1.0 Installation Considerations Figure 2: Wall Mounting Locations (top view) Mount the RF1100 on flat surfaces such as ceilings and walls. Mount the unit to optimize glass break detection. Refer to Figure 2 and Figure 3 for mounting examples. 1 In normal residential or commercial applications, locate the RF1100 within 325 ft (100 m) of its assigned receiver.
RF1100 | Installation Instructions | 2.0 Setup 2.0 Setup 1. 2. 3. 2.1 1. 2. Figure 5: Sensitivity Switch Carefully open the service door (Item 3 in Figure 4) and insert the two AA batteries (supplied), observing the correct polarity. Select a mounting location (refer to Section 1.0 Installation Considerations on page 3). Temporarily mount the unit so you can remove it as needed. 1 2 3 5 EVENT Sensitivity Setting If the front housing is attached, carefully open the service door (Item 4 in Figure 5).
RF1100 | Installation Instructions | 2.0 Setup . 2.2 2.2.2 Testing Test the RF1100 at least once each year. Test the detector with the 13-332 Sound Sensor Tester. Figure 6: 13-332 Sound Sensor Tester ACTIVATE TEST 2 FLEX 3 MAN 1. 2. 3. 4. 4 5. 1 1 - 13-332 2 - Activate/Test switch 2.2.1 3 - Start button 4 - Flex/Man switch Entering Test Mode Place the RF1100 in Test Mode before testing the unit. Test Mode enables the RF1100's LED switch (Item 5 in Figure 5 on page 4).
RF1100 | Installation Instructions | 3.0 Mounting the RF1100 2.3 Enabling the Wall Tamper Figure 9: RF1100 Inside Layout Using the wall tamper is optional. To enable the wall tamper: • Use needle-nose pliers to remove the plastic tab on the back of the detector (Figure 7). The wall tamper contact extends through the hole.
RF1100 | Installation Instructions | 4.0 Low Battery Indication . 9. 10. 11. 12. 13. • Tighten the mounting screws to secure the unit in place. Write down the ID number of the RF ID sticker (Item 1 in Figure 9 on page 6). Align the tabs on the cover with the slots on the base and close the cover. Replace the housing screw. To ensure proper detection, re-test the detector’s sensitivity. Refer to Section 2.1 Sensitivity Setting and Section 2.2 Testing on page 5.