User's Manual
Table Of Contents
- ROAMEO Family Wireless Intercom System
- •TR-1800 •AP-1800
- CHAPTER 1 Certification Information
- CHAPTER 2 Introduction
- CHAPTER 3 System Overview
- CHAPTER 4 Site Survey
- CHAPTER 5 Installation
- CHAPTER 6 Basic Operation
- CHAPTER 7 Beltpack Overview
- System Quick Start
- Button Operation – Common
- Menu Structure – Main Menu Access
- Aux Input Menu
- AUX DIM Menu
- Volume Limit Menu
- Headset Select Menu
- Mic Gain
- Sidetone
- Mic Noise Gate
- Hot Mic
- Talk/Listen LED Buttons
- Front Display Brightness
- Top Display Brightness
- LCD Timeout
- Call Tally Talk
- Screen Flip
- Master Talk Switch
- Low Battery Alert
- Call Waiting Alert
- DECT Connection Alert
- Matrix Connection Alert
- Dark Mode Boot Alert
- Key Clicks Alert
- Alerts Levels
- Key Assignments
- Icon Help
- Scroll List
- CHAPTER 8 Access Point Overview
- AP-1800 Front Panel Description
- IPedit Requirements
- IPedit Main Window
- Configuration
- Device Name Field
- Description Field
- Version Field
- IP Address Field
- Netmask Field
- Gateway Address Field
- DNS Server Field
- Domain Name Field
- MAC Address Field
- Use Static IP Settings Check Box
- Disable RSTP Check Box
- Type Field
- Status Field
- Sessions Field
- AP Channels Field
- BP Channels Field
- Sync Display Box
- System ID Field
- PIN Field
- Zone Drop Down Menu
- CODEC Drop Down Menu
- AP ID Number Field
- Sync Master Check Box
- Intercom Alpha Field
- Channel Description Field
- Destination Type Drop Down Menu
- Destination Device Name Field (OMNEO devices and AP-1800 ROAMEO Access Point Only)
- Destination IP Address Field
- Destination Description Field
- Destination Channel Drop Down Menu
- Destination Channel Description Field
- Receiver Latency Field
- DECT BPID
- DECT Zone Selection Field
- Configuration
- CHAPTER 9 Maintenance
- CHAPTER 10 Troubleshooting, Accessories and Replacements
62 Installation ROAMEO System
Bosch Security Systems, Inc.
Technical Manual
F.01U.306.750
Rev. 01
Configure the AP-1800 in IPedit
To configure the Access Point with IPedit, do the following:
IMPORTANT: The user must be signed in to IPedit with network administrator rights to complete these instructions.
1. From the Device Catalog on the left, select the AP-1800.
The Device Information pane populates.
2. In the Description field, enter a unique description for the access point.
3. In the Version field, verify the version information is correct.
4. Verify the IP Address is correct, if using a Static IP Address.
5. Select the Disable RSTP check box to disable the RSTP protocol, if desired.
DECT Information
6. In the System ID field, enter the system ID for the access point. This field accepts a 3-digit hexadecimal number. By
default, this field is set to B2B.
NOTE: All access points in a system must have the same System ID.
7. In the AP ID field, enter the unique AP ID for the access point. The range for this field is 1–254.
8. Select the Sync Master check box if the access point is the master for the entire system.
NOTE: There can be only one master in each system.