User's Manual
Table Of Contents
- ROAMEO Family Wireless Intercom System
- •TR-1800 •AP-1800
- CHAPTER 1 Certification Information
- CHAPTER 2 Introduction
- CHAPTER 3 System Overview
- CHAPTER 4 Site Survey
- CHAPTER 5 Installation
- CHAPTER 6 Basic Operation
- CHAPTER 7 Beltpack Overview
- System Quick Start
- Button Operation – Common
- Menu Structure – Main Menu Access
- Aux Input Menu
- AUX DIM Menu
- Volume Limit Menu
- Headset Select Menu
- Mic Gain
- Sidetone
- Mic Noise Gate
- Hot Mic
- Talk/Listen LED Buttons
- Front Display Brightness
- Top Display Brightness
- LCD Timeout
- Call Tally Talk
- Screen Flip
- Master Talk Switch
- Low Battery Alert
- Call Waiting Alert
- DECT Connection Alert
- Matrix Connection Alert
- Dark Mode Boot Alert
- Key Clicks Alert
- Alerts Levels
- Key Assignments
- Icon Help
- Scroll List
- CHAPTER 8 Access Point Overview
- AP-1800 Front Panel Description
- IPedit Requirements
- IPedit Main Window
- Configuration
- Device Name Field
- Description Field
- Version Field
- IP Address Field
- Netmask Field
- Gateway Address Field
- DNS Server Field
- Domain Name Field
- MAC Address Field
- Use Static IP Settings Check Box
- Disable RSTP Check Box
- Type Field
- Status Field
- Sessions Field
- AP Channels Field
- BP Channels Field
- Sync Display Box
- System ID Field
- PIN Field
- Zone Drop Down Menu
- CODEC Drop Down Menu
- AP ID Number Field
- Sync Master Check Box
- Intercom Alpha Field
- Channel Description Field
- Destination Type Drop Down Menu
- Destination Device Name Field (OMNEO devices and AP-1800 ROAMEO Access Point Only)
- Destination IP Address Field
- Destination Description Field
- Destination Channel Drop Down Menu
- Destination Channel Description Field
- Receiver Latency Field
- DECT BPID
- DECT Zone Selection Field
- Configuration
- CHAPTER 9 Maintenance
- CHAPTER 10 Troubleshooting, Accessories and Replacements
60 Installation ROAMEO System
Bosch Security Systems, Inc.
Technical Manual
F.01U.306.750
Rev. 01
Add the OMI to the Device Catalog in IPedit
To add the OMI to IPedit, do the following:
1. Open IPedit.
2. From the Device menu, select Add.
The Add Devices Window appears, open to the Search tab.
3. Select the OMI card.
The Add button becomes active.
4. Click the Add button.
The OMI card appears in the device catalog in the left panel.
5. Click the Done button.
The Add Devices window closes.
Configure the OMI using IPedit
To configure the OMI using IPedit, do the following:
Using the Device Configuration and Status Pane
1. In the Device Name field, enter the device name.
Initially, OMI cards are given a default name.
IMPORTANT: Changing the device name causes the device to reboot. It is not necessary to change the device name.
However, if changed, it is best to do this early in the setup so revisiting other devices that connect to this
device and updating them later is not necessary.
2. In the Description field, enter a description for the OMI card, if desired.
Using the Channel Configuration and Status Pane
3. In the Channel Description field, enter a channel description, if applicable.
4. From the Destination Type drop down menu, select OAP-5 or OAP-10.
NOTE: The Destination Type does not need to be selected if using the Browse window to select the device. It fills
the Type and IP Address automatically. The type is either OAP-5 (OMNEO Access Point - 5 Channel) or
OAP-10 (OMNEO Access Point - 10 Channel) depending on the CODEC configured on the device.
5. In the Destination Device Name field, enter the name of the device to which the channel will connect.
OR
Click the ... button.
The Discovered Devices Window appears.
a. Expand the tree to view the destination devices available.
b. From the expanded tree, select the destination device.
c. Click OK.
6. From the Destination Channel drop down menu, select the channel to which the OMI will connect.
7. Send the changes to the OMI.