146 Maintenance ROAMEO System
Bosch Security Systems, Inc.
Technical Manual
F.01U.306.750
Rev. 01
Add a Beltpack to the System
If problems are encountered, see “Cannot download the firmware update to the beltpack” on page 154.
To add a beltpack to the system, do the following:
Step 1 Find the access point which is to be the Home access point for the beltpack.
Step 2 Add BPID to the specific channel assigned to connect the beltpack.
Step 3 Send Changes.
Step 4 Subscribe the beltpack to the system. See “Subscribe the Beltpack and Connect to the Access Point” on
page 70.
Update the Splash Screen on the TR-1800 ROAMEO Beltpack
If problems are encountered, see “Cannot download the firmware update to the beltpack” on page 154.
To update the TR-1800 ROAMEO beltpack splash, do the following:
1. On the front of the beltpack, press the MENU button.
The startup screen appears.
2. Press the MENU button again.
The MENU icons appear in the beltpack display screen.
3. Using the DOWN arrow button, navigate to the Settings icon.
4. Press the SELECT button.
The Settings submenu icons appear in the beltpack display screen.
5. Using the DOWN arrow button, navigate to the Update icon.
6. Press the SELECT button.
Application, Bootloader, Unicode Fonts, Splash Image, and DECT module appear in the beltpack display screen.
7. Using the DOWN arrow button, navigate to Splash Image.
8. Press the SELECT button.
The message Plug in the USB Stick appears in the beltpack display screen.
9. Plug the approved USB into the bottom panel USB connector. See Figure 1 on page 16.
A list of splash screen images appear on the beltpack display screen.
10. Using the UP and DOWN arrow buttons, select the splash image to upload.
11. Press the SELECT button.
The message Splash Update Uploading and a progression bar appear on the beltpack display screen.
NOTE: Once the splash update completes, the beltpack reboots itself.
12. Remove the USB stick.
13. Cycle the power on the beltpack to see the splash screen changes.