15. In the Destination Device Name field, enter the name of the OMI card to which the channel is connected.
OR
Click the browse button.
The Discovered Devices window appears.
a. Expand the tree to view the available destination devices.
b. From the expanded tree, select the destination device.
c. Click OK.
The Discovered Devices window closes.
16. From the Destination Channel drop down menu, select the destination channel to which the channel is connected.
17. In the DECT BPID, enter the beltpack ID to assign to that channel.
NOTE: For information on obtaining the beltpack ID, see “Configure the Beltpack to its Home AP-1800” on
page 65.
18. In the DECT Zone Selections field, enter the zone the beltpack is permitted to operate in (the default is zone one).
OR
From the DECT Zone drop down menu, select the check box next to each zone to assign to the beltpack.
NOTE: At least one zone must be selected for the beltpack. Any combination of zones may be selected.
19. From the Changes menu, select Send.
20. From the File menu, click Save.