3. From the Device menu, select Add.
The Add Devices window appears.
4. Select the access point (displays as the device type OAP-5 or OAP-10).
5. Click Add.
The access point appears in the Device Catalog in the left pane.
6. Click Done.
Assign the TR-1800 to an AP-1800 Channel
To assign the TR-1800 to an AP-1800 channel, do the following:
1. From the Device Catalog on the left, select the AP-1800.
The Device Information fields populate.
2. Select the Sync Master check box to set the AP-1800 to Sync Master.
IMPORTANT: On a piece of paper, note the 3-digit System ID (the default is B2B) and the 4-digit PIN (the default is
0000) of the access point. These are used later to subscribe the beltpack to the access point.
3. Power up the TR-1800.
The BPID displays on the front panel. This is a 10-digit, hexadecimal number (for example, 00:09:22:B5:21).
4. In the DECT BPID field, enter the beltpack ID to assign to that channel.
5. From the Changes menu, select Send All.
The Send Changes window appears.
6. Click OK.
The changes are sent to the AP-1800 and then it resets. After approximately one minute, the Sync check box turns
green. The AP-1800 stores the BPID, even if power is disconnected (for example, in non-volatile memory).
Subscribe the TR-1800 to the AP-1800
To subscribe the TR-1800 to the AP-1800, do the following:
IMPORTANT: Be sure the beltpack is within 40 feet (12 meters) of the AP-1800.
1. With the AP-1800 running, power up the TR-1800.
The front color display panel activates.
2. Press the Menu button.
The beltpack main menu appears.