User's Manual
Table Of Contents
- ROAMEO Family Wireless Intercom System
- •TR-1800 •AP-1800
- CHAPTER 1 Certification Information
- CHAPTER 2 Introduction
- CHAPTER 3 System Overview
- CHAPTER 4 Site Survey
- CHAPTER 5 Installation
- CHAPTER 6 Basic Operation
- CHAPTER 7 Beltpack Overview
- System Quick Start
- Button Operation – Common
- Menu Structure – Main Menu Access
- Aux Input Menu
- AUX DIM Menu
- Volume Limit Menu
- Headset Select Menu
- Mic Gain
- Sidetone
- Mic Noise Gate
- Hot Mic
- Talk/Listen LED Buttons
- Front Display Brightness
- Top Display Brightness
- LCD Timeout
- Call Tally Talk
- Screen Flip
- Master Talk Switch
- Low Battery Alert
- Call Waiting Alert
- DECT Connection Alert
- Matrix Connection Alert
- Dark Mode Boot Alert
- Key Clicks Alert
- Alerts Levels
- Key Assignments
- Icon Help
- Scroll List
- CHAPTER 8 Access Point Overview
- AP-1800 Front Panel Description
- IPedit Requirements
- IPedit Main Window
- Configuration
- Device Name Field
- Description Field
- Version Field
- IP Address Field
- Netmask Field
- Gateway Address Field
- DNS Server Field
- Domain Name Field
- MAC Address Field
- Use Static IP Settings Check Box
- Disable RSTP Check Box
- Type Field
- Status Field
- Sessions Field
- AP Channels Field
- BP Channels Field
- Sync Display Box
- System ID Field
- PIN Field
- Zone Drop Down Menu
- CODEC Drop Down Menu
- AP ID Number Field
- Sync Master Check Box
- Intercom Alpha Field
- Channel Description Field
- Destination Type Drop Down Menu
- Destination Device Name Field (OMNEO devices and AP-1800 ROAMEO Access Point Only)
- Destination IP Address Field
- Destination Description Field
- Destination Channel Drop Down Menu
- Destination Channel Description Field
- Receiver Latency Field
- DECT BPID
- DECT Zone Selection Field
- Configuration
- CHAPTER 9 Maintenance
- CHAPTER 10 Troubleshooting, Accessories and Replacements
44 Site Survey ROAMEO System
Bosch Security Systems, Inc.
Technical Manual
F.01U.306.750
Rev. 01
3. From the Device menu, select Add.
The Add Devices window appears.
4. Select the access point (displays as the device type OAP-5 or OAP-10).
5. Click Add.
The access point appears in the Device Catalog in the left pane.
6. Click Done.
Assign the TR-1800 to an AP-1800 Channel
To assign the TR-1800 to an AP-1800 channel, do the following:
1. From the Device Catalog on the left, select the AP-1800.
The Device Information fields populate.
2. Select the Sync Master check box to set the AP-1800 to Sync Master.
IMPORTANT: On a piece of paper, note the 3-digit System ID (the default is B2B) and the 4-digit PIN (the default is
0000) of the access point. These are used later to subscribe the beltpack to the access point.
3. Power up the TR-1800.
The BPID displays on the front panel. This is a 10-digit, hexadecimal number (for example, 00:09:22:B5:21).
4. In the DECT BPID field, enter the beltpack ID to assign to that channel.
5. From the Changes menu, select Send All.
The Send Changes window appears.
6. Click OK.
The changes are sent to the AP-1800 and then it resets. After approximately one minute, the Sync check box turns
green. The AP-1800 stores the BPID, even if power is disconnected (for example, in non-volatile memory).
Subscribe the TR-1800 to the AP-1800
To subscribe the TR-1800 to the AP-1800, do the following:
IMPORTANT: Be sure the beltpack is within 40 feet (12 meters) of the AP-1800.
1. With the AP-1800 running, power up the TR-1800.
The front color display panel activates.
2. Press the Menu button.
The beltpack main menu appears.