17.4.2 Loop-through socket
With the loop-through socket, you can connect battery
chargers in series.
• If the power supply is 100 - 127 V(AC), 50 - 60 Hz,
you can connect a maximum of 5 battery chargers in
series.
• If the power supply is 220 - 240 V(AC), 50 - 60 Hz,
you can connect a maximum of 10 battery chargers
in series.
17.5 Ope rat i on
The higher the capacity, the higher the number of
charge level LEDs that come on (refer to table 16.4).
figure 17.6: Loop-through socket
Note
The accuracy of the battery capacity in table
16.4 is plus or minus 20%.
table 17.2: Charge level LEDs
No. LEDs on Battery capacity (hours)
518 - 20
4 13 - 18
38 - 13
2 3 - 8
1< 3