User's Manual Part 2
Table Of Contents
- Section 2 - Central Devices
- 10 DCN-WCCU Wireless Central Control Unit
- 11 DCN-WAP Wireless Access Point
- 12 System configuration
- 13 System operation
- Section 3 - Contribution Devices
- 14 DCN-WDU Wireless Discussion Units
- 15 DCN-MICL, DCN-MICS Pluggable Microphones
- 16 DCN-WLIION Battery Pack
- 17 DCN-WCH05 Battery Charger
- 18 DCN-WPS Power Supply Adapter
- 19 DCN-DDI Dual Delegate Interface
- 20 DCN-WFCD10 Flight Case for Wireless Discussion Units
- 21 DCN-WFCCU Flight Case for DCN-WCCU and DCN-WAP
- Section 4 - Appendices
Bosch Security Systems | 2007-02 | 9922 141 70691 en
DCN Wireless | Installation and User Instructions | Central Devices en | 41
10.3.2 S600 switches
10.3.3 RS232 configuration
Use the S500 switches to configure the RS232 ports of
the central control unit (refer to table 10.2 and table
10.3).
table 10.1: S600 switches (* = default)
Switch Position Description
S600-1 ON*
OFF
Reserved. Do not change the position of this switch.
S600-2 ON
OFF*
Reserved. Do not change the position of this switch.
S600-3 ON
OFF*
Reserved. Do not change the position of this switch.
S600-4 ON
OFF*
Reserved. Do not change the position of this switch.
S600-5 ON
OFF*
Reserved. Do not change the position of this switch.
S600-6 ON
OFF*
Reserved. Do not change the position of this switch.
S600-7 ON
OFF*
Reserved. Do not change the position of this switch.
S600-8 ON
OFF*
Enables the download of new firmware.
Normal operation.
table 10.2: RS232 protocol (* = default)
Protocol Port 1 Port 2
S500-1 S500-2 S500-5 S500-6
Open interface Off Off Off Off
Terminal Off On Off On
Full On* Off* On Off
Camera control On On On* On*
table 10.3: RS232 baudrate (* = default)
Baudrate Port 1 Port 2
S500-3 S500-4 S500-7 S500-8
9.6k Off Off Off Off
19.2k Off On Off* On*
57.6k On Off On Off
115.2k On* On* On On