2.8.2 Power correction
figure 2.5: Example with interpreter desks (DCN-IDESK)
LBB4 11 4/00
50 m 20 m
LBB4 11 4/00LBB4 11 4/00
LBB4 11 4/00
LBB4 11 4/00
3
3
4
4
4
2
2
2
2
2
NCCCNO
Fault
RS 232
Network
12
AudioIn 1 Audio Out 1 Audio In 2 Audio Out 2
Mains
Port 2
115:100-120V 50-60Hz T2.5A 250V
230:220-240V 50-60Hz
T2A H 250V
RS 232 Port 1
Trunk
12
48V 48V
230
DCN-WCCU
10 m
table 2.3: Example with interpreter desks (DCN-IDESK)
Socket Power for devices Cable length Corrected power
Trunk 1 50.7 W 50 m 64.0 W
Trunk 2 56.6 W 30 m 64.7 W