User Manual

27
Chapter 7: Firmware Documentation
The current firmware is 1.2.5 - 1.1.1 – 1.5.6. This is Ethernet PCB firmware version 1.2.5 and
PRISM firmware 1.1.1 (primary) and 1.5.6 (secondary). To upgrade firmware, ensure that the
CPE and attached computer are on the same subnet, then run the supplied Locator tool.
1.2.5-1.1.1-1.5.6 Release Notes:
Default settings:
IP: 192.168.1.99
SSID: (empty)
No WEP, no user name, no password
Disallow firmware upgrades
1.2.5 (2 December 2003)
- Fixed a problem with TCP deadlocking when receiving data from a remote host but being
unable to make progress retransmitting a lost segment.
- Cleaned up web server’s error recovery on aborted requests.
- Added BSSID and RSSI to syslog mark messages.
- Improved RSSI and noise level dBm readings.
- Fixed wrong MAC address displayed by Locator.
- Now show the device the bridge is associated with on the Scan List page, but not
clickable.
- Changed the bandwidth control: now account for protocol headers (Ethernet, IP, TCP and
UDP) in the bandwidth calculation. Also, ICMP and IGMP packets are not bandwidth
limited anymore.
1.2.2 (25 August 2003)
- Fixed typos in help pages.
- Fixed web server port problem.
- Fixed a bunch of small items.
1.2.1 (25 July 2003)
- Fixed self-programming LED’s.
- Fixed typo in WEP help page.
- Fixed scan list signal level.
1.2.0 (22 July 2003)
- Added syslog client.
- Added ability to deny access to the web UI from Ethernet or WLAN.
- TFTP server disabled by default.
- Added support for Locator Utility Tool.
- Changed default settings for SSID to “none”.