User's Manual

Certifications and approvals
The product is classified in accordance with the
following standards:
• FCC part 15.231
• ETSI EN300 (433.42 Mhz)
• RCM
Installation/configuration notes
Installation
The coordinator is for indoor and outdoor use. The
coordinator mounts in one of two different sized
enclosures. Connect the receivers to the coordinator
using one 3‑wire multiplex buses: two wires for data
(A and B) and one wire for GND. Each bus supports 1
built-in receiver of the coordinator and up to 15
external receivers. A Security Escort System supports
up to 1024 coordinators and a total of 16384 devices.
Mounting Considerations
You will need a Security Hex Driver to mount the
receiver.
• Indoor Enclosure: Mount on inside walls.
• Outdoor Enclosure: Mount on the sides of buildings
and on light posts.
Compatibility Information
Central Console
Software
SE3000 Series
AT receiver ATX-RCV-MT01
AT transmitter ATX-TRM-304T01, ATX-TRM-433T01
Transmitter SE2 Series, SE3 Series, SE3401 and SE88
Series
Parts included
Quantity Component
1 ALLPLEX track Coordinator
1 ALLPLEX track Coordinator & Receiver Installation Manual
4 2.2 kΩ Axial Lead Resistors
Technical specifications
Transmission
Frequency 303.825 / 304 (default) / 433.42 MHz
selectable by Dip Switch
Trouble Output Signal sent through the central console
Antenna Type Internal
Sensitivity
Adjustments
-100 dB minimum
Electrical
Power Consumption 200mA @ +12VDC (max)
Operating Input
Voltage
10.8 – 13.2V
Primary Power
Source
Power over Ethernet (PoE)
(PoE standard: IEEE 802.3af-2003 and IEEE
802.3at-2009 Type 1)
Secondary Power
Source
12V DC in
Environmental
Operating
Temperature
-30°C to +65°C
(-22°F to +149°F)
Hardware
Input 2 analog inputs
(4 state supervised monitoring)
Output 2 relay outputs
(Relay dry contact, 1A @ 30V DC)
Communication
Interface
Ethernet 10/100 BaseT (central console)
RS-485 / Wireless radio frequency (receivers)
Housing Tamper Normally closed (NC)
Reliability
Mean Time Between
Failures (MTBF)
10 years
Ordering information
ALLPLEX track Coordinator
Controls ALLPLEX track receivers. Relays alarm and
test signals from the receivers to the central console.
Selectable frequencies of 303.825 / 304 / 433.42 MHz
by dip switch.
Order number ATX-COR-MT01
2 | ALLPLEX track Coordinator