Installation Manual

Radio Frequency Switch Number on Dip Switch SW2
1 2
433.42 MHz ON OFF
Invalid setting ON ON
Table 5.3: Radio frequency (RF) settings on dip switch SW2
Once configured, you can confirm the RF settings every time you power up the coordinator/
receiver by observing the tricolor LED. For more information, refer to Checking the radio
frequency (RF), page 27.
Selecting the hard/soft reset mode
There are two reset modes for the coordinator/receiver, namely the hard or soft reset. To
select the reset mode, use dip switch SW2. Set switch number 3 based on the following table.
Reset Mode Switch Number on Dip Switch SW2
3
Soft reset (default setting) OFF
Hard reset ON
Table 5.4: Reset mode on dip switch SW2
Pressing the Reset button on the coordinator/receiver performs the hard or soft reset
accordingly. The differences of the reset mode are described in Resetting the coordinator/
receiver, page 27.
Setting the baud rate
Configure the baud rate of the RS-485 communication by using the dip switch on the right,
SW2. The same baud rate must be set across the coordinator and the receivers in order for
the RS-485 communication to work. Use the switch numbers 4 and 5 on dip switch SW2 to set
the baud rate. The options are described in the following table.
Baud Rate Switch Number on Dip Switch SW2
4 5
19200 (default setting) OFF OFF
38400 OFF ON
57600 ON OFF
115200 ON ON
Table 5.5: Setting the baud rate on dip switch SW2
5.3
5.4
ALLPLEX track Coordinator & Receiver Setting the Switches and Jumpers | en 21
Robert Bosch (SEA) Pte Ltd Installation Guide 2014.03 | V1.0.0 | F.01U.277.701