User Manual

8/8 Bosch Rexroth AG
HDD RE 95 135/06.06
© This document, as well as the data, specifications and other information
set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
reproduced or given to third parties without its consent.
The data specified above only serve to describe the product. No statements
concerning a certain condition or suitability for a certain application can be
derived from our information. The information given does not release the user
from the obligation of own judgment and verification. It must be remembered that
our products are subject to a natural process of wear and aging.
Subject to change.
Bosch Rexroth AG
Hydraulics
Product Segment Axial Piston Units
Elchingen Plant
Glockeraustrasse 2
89275 Elchingen, Germany
Phone +49 (0) 73 08 82-0
Facsimile +49 (0) 73 08 72 74
info.brm-ak@boschrexroth.de
www.boschrexroth.com/brm
General Notes
The suggested circuits do not imply any technical liability of Rexroth for the system.
Lines to sensors must be shielded. The shield must be connected to the electronics on one side or to the machine or vehicle
ground via a low-impedance connection.
Lines to the electronic unit must not be routed close to other power-conducting lines in the machine or vehicle.
A sufficiently large distance to radio systems must be maintained.
All connectors must be unplugged from the electronic unit during electrical welding operations.
In the case of the HDD2 speed sensor, if longer connecting lines are used (> 5 m long), the lines for each frequency signal
should be separately shielded.