User Manual
Table Of Contents
6/20 Bosch Rexroth AG
RC RE 95203/11.07
Technical Data
Controller RC36-20/30
Nominal voltage
12 and 24 V
Residual ripple (DIN 40839, Part 1) max. ± 2 V
Supply voltage, permitted range 8 - 32 V
Current consumption
Without load, in 12 V system 380 mA
Without load, in 24 V system 290 mA
With load, in 12 V system max. 50 A
With load, in 24 V system max. 25 A
Fuse
Internal: –
External: in supply path AT 50
Controller release pin
Terminal 15
Constant voltage sources
3)
E.g. for setpoint potentiometer
1000 mA 10 V ± 350 mV
500 mA
5 V ± 150 mV
Digital voltage inputs, diagnostics-compatible
32
Analog voltage inputs, pull-down 0 - 10 V 7
0 - 32 V 2
Analog current inputs, diagnostics-compatible
0 - 20 mA 12
Resistor inputs
4
E.g. for temperature sensors
Resistance measuring range 800 - 1800 Ω
Frequency inputs total
10
DSM 7 mA/14 mA 6
Inductive sensors 0 - 10 kHz level > 1 V
eff
2
Active sensors 0 - 20 kHz 2
Level low < 1 V
Level high > 6 V
Analog current outputs
1
For 200 Ohm load (burden) 4 - 20 mA
Proportional solenoid outputs (PWM)
36
Current range, highside 0 - 2.0 A
2)
Pulsation frequency 100 - 350 Hz
Digital output stages total
20
Current range, highside max 1.8 A
2)
12
Current range, highside max 0.5 A 8
Interfaces
4
CAN 2.0 B, ISO 11898
Fault detection for cable break and short circuit
Analog inputs
Proportional solenoid outputs
Switching solenoid outputs
Protection against short circuit
Against supply voltage and ground
For all inputs and outputs
1
)
3
)
Reverse-connect protection
Voltage supply / battery
1
) Exceptions: GND, sensor GND against battery
2
) Max. cumulative current per group: 5 A
3
) Sensor voltage inputs are raised in case of short circuit to battery.
A correct reading of sensor signals is no longer guaranteed.