User Manual
Table Of Contents
RE 95201/11.07 RC
7/16Bosch Rexroth AG
Monitored
potentiometer
2.5 - 5 kΩ
Sensor
power supply
Voltage
input
Current
input
11
)
11
)
Connection Variants
1
) Short, low-resistance connection from a case screw to the device ground or vehicle ground
2
) Separate ground connection from solenoid return line to battery (chassis possible)
3
) Separate fuses for switches and sensors necessary
4
) CAN bus: termination resistor 120
Ω
necessary
5
) Sensor supply voltage for potentiometers and active sensors
6
) Can be switched together between high / low active by means of software - pull-up or pull-down for these inputs
7
) Separate ground connection for current source to battery, controller GND possible (pins 38/49)
8
) If ≥ 5 V is applied to the input, all power outputs are off
9
) Can be used as switch inputs if externally switched to GND
10
) The terminals are labeled according to DIN 72 552. This does not apply for the controller.
11