User Manual

8/12 Bosch Rexroth AG
RCE RE 95220/11.07
Dimensions RCE12-4/22

NBY

 



NBY

NBY

NBY

NJO
B
C
D
E


 



 
 

 
 
 
 

 
 
 
³®
®
®
®
®
®
Installation Position
Note:
Installation position only permissible with specified angular range.
Fixing:
The BODAS CAN I/O extension module must be fixed at
4 points (a, b, c, and d).
Tightening torque MA = 8 ± 2 Nm for fixing the BODAS
CAN I/O extension module with M6 screws.
Tightening torque applies for mounting without washer.
The equivalent tightening torque must be calculated when
using washers.
Rexroth’s approval is required if mounting is different from
above.
Installation point: evenness of mounting surface
0.5
The wiring harness should be fixated mechanically in
the area in which the controller is installed (spacing
< 150 mm).
The wiring harness should be fixated such that a phase
excitation with the controller occurs (e.g. at the controller
mounting point).
If the mounting surface is not sufficiently even, place flexible
compensating elements (e.g. rubber washers) between the
fixing points of the BODAS controller and the mounting
surface.
1
) Space required for mating connector
2
) Space required for plugging and unplugging the mating
connector