• Notes on circuitry and on wiring:
The lines used for speed sensors are to be shielded. The shield must be connected to the electronics on one side or to the
machine or vehicle ground via a low-resistance connection.
Cables to the electronics must not be routed close to other power-conducting lines in the machine or vehicle.
– The electronics and the power outputs of a controller must be fed from the same power source.
– The wiring harness should be fixated mechanically in the area in which the controller is installed (spacing < 150mm).
The wiring harness should be fixated such that a phase excitation with the controller occurs
(e.g. at the controller mounting point).
– When wiring the output stages, the maximum cumulative output current for each output stage group should be noted. The
cumulative output current means a permanent, simultaneous actuation of the output stages.
• Notes on proportional solenoids and switching solenoids and other switched inductive consumers:
The electronics may only be tested with the proportional solenoids connected.
The proportional solenoids must not be wired with suppression diodes.
Switching solenoids at the outputs of the controller RC do not need to be connected to suppression diodes.
Other inductive loads that are in the system but not connected to the controller RC must be connected to
suppression diodes.
Safety features in the RCE
Faults in the supply voltage are detected by internal monitoring.
All output signals can be monitored by the microcontroller with the appropriate software.
For service purposes, the controllers can be operated with all power outputs de-energized.
The internal watchdog module centrally switches off all proportional and switched outputs in the event of disturbances to the
program execution.
Product-specific notes
Via the release input, the output stages (proportional and switched outputs) are switched off independent of the CAN bus.
Safety Notes