User Manual

Bosch Rexroth AG
Open and Closed Loop Speed Control SPC RE 95300/12.07
15/16
Figure 10: Inputs and outputs on the controller for SPCD
SPCD Connection Diagram
2
)
33
32
37
48
30
1
)
51
50
17
40
52
39
TxD
RS232 RxD
CAN H
CAN L
C
D
B
E
A
G
F
H
+5V
10
11
34
47
46
49
36
35
38
5)
+5V
5)
2
)
31
29
45
44
43
2
)
4
)
10 A
0 V
30
+12 V/+24 V
+
31
3 A
3 )
6 )
1 A
30 15
2
28
41
42
1
27
Voltage supply
electronics
Supply for
power outputs
Speed sensor
(HDD2)
Fill level sensor
Left pushbutton
Right pushbutton
Frequency inputs
Sensor supplyVoltage inputs
Current inputs
Switch inputs
Inter-
face 1
Reserved
Inter-
face 2
Pump counterclockwise
Pump clockwise
Error lamp
Status lamp for
funnel function
Diagnostics connector
for BODAS service
Switch between
mixing operation/
funnel function
Proportional
outputs
Switched
outputs
1)
Short, low-resistance connection from a case screw to the vehicle ground
2)
Separate ground connection to battery (chassis possible)
3)
Separate fuses recommended for switches and sensors and electronics
4)
CAN bus: 120 W termination resistor recommended (see installation instructions RDE 90 300-01)
5)
5V / ground outputs may also be used alternatively as sensor supply
6)
Observe maximum current consumption where proportional solenoids and switched outputs are controlled
simultaneously
7)
The terminals are labeled according to DIN 72 552. This does not apply for the controller.
Safety
switch
Ignition switch
7)