Components Required
The following electronic components are needed:
• BODAS controller RC2-2/21 with mating connector,
52-pin (RD 95201)
• BODAS AS/AFC software, version 20
The following hydraulic components are needed:
Hydraulic concept A
• Variable pump with A10VO…ED electrohydraulic pressure
control (RE
92707)
• AZM fi xed motor (RE 14026)
Hydraulic concept B
• AZP fi xed pump
– Series F (RE 10089)
–
Series B (RE 10087)
–
Series N (RE 10091)
–
Series G (RE 10093)
• AZMF fi xed motor (RE 14026)
The following electronic components can be used:
• PTC temperature sensor for air
TSA ( R E 95181)
• PTC temperature sensor for fl uids TS F (R E 95180 )
• Switch for digital inputs
• Error lamp
• Reversing valve
The following are required for commissioning and service:
•
BODAS-service PC software (RE 95086)
• BODAS-service connection cable (RE 95086)
• Diagnostic socket (RE 95086)
Parameter Settings and
Diagnostics
The parameters to be set when commissioning the AFC20 fan
control can easily be adjusted using the BODAS-service PC
software.
You can confi gure BODAS-service to display the most
important process variables and the error messages for fault
diagnostics and troubleshooting purposes.