Components Required
The following electronic components are needed:
BODAS controller RC2-2/21 with mating connector,
52-pin (RD 95201)
BODAS AS/AFC software, version 20
The following hydraulic components are needed:
Hydraulic concept A
Variable pump with A10VO…ED electrohydraulic pressure
control (RE
92707)
AZM fi xed motor (RE 14026)
Hydraulic concept B
AZP fi xed pump
Series F (RE 10089)
Series B (RE 10087)
Series N (RE 10091)
Series G (RE 10093)
AZMF xed motor (RE 14026)
The following electronic components can be used:
PTC temperature sensor for air
TSA ( R E 95181)
PTC temperature sensor for fl uids TS F (R E 95180 )
Switch for digital inputs
Error lamp
Reversing valve
The following are required for commissioning and service:
BODAS-service PC software (RE 95086)
BODAS-service connection cable (RE 95086)
Diagnostic socket (RE 95086)
Parameter Settings and
Diagnostics
The parameters to be set when commissioning the AFC20 fan
control can easily be adjusted using the BODAS-service PC
software.
You can confi gure BODAS-service to display the most
important process variables and the error messages for fault
diagnostics and troubleshooting purposes.